5. FAULT TRACING
When a fault occurs in the battery charger, the following table can be used in order to find the
fault. Before the Titan is being checked, make sure that all the devices connected to the
battery charger are removed. If the fault can not be solved contact your Victron Energy
dealer.
Problem Possible cause Solution
The charger does not
operate
The mains voltage has to be between
185Vac and 265 Vac. (For the 24/30
110V, between: 93,5 and 132 Vac).
Measure the mains voltage and make sure it is in
between 185Vac and 265Vac. (For the 24/30
110V, between: 93,5 and 132 Vac).
A broken input fuse. Return the charger to your dealer.
The battery is not
being fully charged
The equalize-charge mode is set to
a too short period.
Set the equalize-charge mode to a longer time.
A bad battery connection. Check the battery connections.
The boost charge voltage is
set to a wrong value.
Adjust the boost charge voltage to the right
value.
The float charge voltage is
set to a wrong value.
Adjust the float charge voltage to the right
value.
The battery temperature is too high. Connect the temperature sensor.
The capacity of the battery is too large. Connect a battery with a smaller capacity or
install a larger charger.
The output fuses are broken. Replace the output fuses.
The battery is being
overcharged
The battery charger is set into the
permanent boost-charge mode.
Deselect the permanent boost DIP-switch
(Rboost).
The boost charge voltage is
set to a wrong value.
Adjust the boost charge voltage to the right
value.
The float charge voltage is
set to a wrong value.
Adjust the float charge voltage to right value.
A bad battery. Check the battery.
The battery is too small. Reduce the charge current.
The failure led
illuminates
The charger is switched off as a result
of a high ambient temperature.
Place the charger in a cooler, or better ventilated
place.
The failure led
flashes
The charger is reducing the output
current as a result of a high ambient
temperature.
Place the charger in a cooler, or better ventilated
place.
The failure led
flashes in a code
1
The output fuses are broken. Replace the output fuses.
The failure led
illuminates in
combination with a
blinking on/off led
There is a voltage drop higher than 2V
across the battery cables.
Turn the charger off, replace battery cables and
connect them well.
1
Flashing code sequence is two times on in one second and then one second off.
The cover of the Titan may only be removed by a qualified technician.
Before obtaining access to the Titan the mains supply circuit must be
disconnected.