USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG PALLAS-TG 12/50 SKYLLA-TG 24/30 SKYLLA-TG 24/50 SKYLLA-TG 24/30 110V TITAN 48/25
8 Manual Titan The Titan charger can remain connected to the battery continuously, without gas formation taking place, caused by overcharging.
Manual Titan 9 2.3 Protection The battery charger is safe to use due to its robust design and its internal electronic protection. This chapte
10 Manual Titan Temperature protection The internal temperature of the charger is measured continuously. However, due to a high ambient temp
Manual Titan 11 3. DIRECTIONS FOR USE 3.1 Installation Find a dry and well-ventilated area to mount the Titan charger and battery. Keep the di
12 Manual Titan - starter battery connection+ starter battery connectionGreen ledNegative battery connectionOutput fusesPositive battery con
Manual Titan 13 Connecting the starter battery The starter battery has to be connected using wire with a core of at least 1.5 mm2. Connect t
14 Manual Titan 3.2 Operation Located on the front of the Titan charger are an on/off switch and three rows of LED’s, as shown in illustratio
Manual Titan 15 After the batteries are charged the Titan charger does not have to be switched off and the batteries can stay connected to the
16 Manual Titan 4. OPTIONS The Titan charger is factory set to standard values. Some of these standard values can be changed by a qualified el
Manual Titan 17 4.1 Permanent boost-charge In some cases, for example when the battery is almost empty, it is recommended to permanent boost-ch
18 Manual Titan To change the boost-voltage: Place DIP-switch 7 “Eq2” to the right and place DIP-switch 8 “R boost” to the left. The charger
Manual Titan 19 4.5 Traction battery compensation If a Traction-battery is connected to the Titan charger the charge voltages have to be change
20 Manual Titan 4.8 Charging batteries with voltage sensing When high current runs trough a thin cable between the charger and the ba
Manual Titan 21 start charging in the boost mode. When dip switch 2 “Watch” is positioned on the right, it is checked upon startup whether the
22 Manual Titan With the CSV panel the charger can be switched on or off. On the panel a green “on” led is present. To operate the CSV panel
Manual Titan 23 Connect the other pole of the switch to the “GND” connector. 4.14 Connecting a voltmeter The remote-connector offers a pos
24 Manual Titan 5. FAULT TRACING When a fault occurs in the battery charger, the following table can be used in order to find the fault. Befor
Manual Titan 25 6. TECHNICAL SPECIFICATIONS 6.1 General Switch on behaviour Charger can switch on under every load Efficiency 12/50
26 Manual Titan Model TG 12/50 TG 24/30 24/30 110V TG 24/50 TG 48/25 Voltage compensation for diode-splitter, via DIP-switch + 0,6 V
Manual Titan 27
Manual Titan 1 SECTIONS Page English 3 Nederlands 29 Deutsch 55
28 Manual Titan © victron energy b.v.Pallas-TG 12/50, Skylla-TG 24/30, 24/30 110VacSkylla -TG 24/50 and Titan 48/25 dimensionsdrawing no.: TI0
Manual Titan 29 Victron Energy B.V. The Netherlands Phone: ++ 31 (0) 36 535 97 00 Fax: ++ 31 (0) 36 531 16
2 Manual Titan Copyrights 2003 Victron Energy B.V. All Rights Reserved This publication or parts thereof, may not be reproduced in any form
Manual Titan 3 USER MANUAL PALLAS-TG 12/50 SKYLLA-TG 24/30 SKYLLA-TG 24/50 SKYLLA-TG 24/30 110V TITAN 48/25
4 Manual Titan USER MANUAL TITAN GENERATION CHARGERS 1. INTRODUCTION 5 1.1 Victron energy 5 1.2 The Titan Generation charger 5 1.3 Warni
Manual Titan 5 1. INTRODUCTION 1.1 Victron energy Victron Energy has established an international reputation as a leading designer and manufac
6 Manual Titan The battery charger is NOT protected against reverse battery polarity. ("+" connected to &q
Manual Titan 7 2. DESCRIPTION 2.1 The Titan battery charger The Titan battery charger is a fully automatic charger for 12V, 24V or 48V batter