Victron energy 24/30 Spezifikationen Seite 3

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 20
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 2
CHARACTERISTICS
PHOENIX INVERTER
230VAC/50HZ
SinusMax - Superior engineering
True sine wave inverter with optimised e ciency but without compromise in performance.
Employing hybrid HF technology, the result is a top quality product with compact
dimensions, light in weight and capable of supplying power, problem-free, to any load.
Extra start-up power
A unique feature of the SinusMax technology is very high start-up power. Phoenix inverters,
however, are well suited to power up di cult loads such as refrigeration compressors,
electric motors and similar appliances.
Virtually unlimited power thanks to parallel and 3-phase operation capability
Up to 6 units Phoenix 24/3000 can operate in parallel to achieve 18KVA power output.
Operation in 3-phase con guration is also possible.
To transfer the load to another AC source: the automatic transfer switch
If an automatic transfer switch is required on models rated at 1200 VA or more, we re-
commend using the Phoenix Multiplus instead. The switch is included in these products
and the charger function of the Multi can be disabled. For our lower power models we
recommend the use of our Filax Automatic Transfer Switch. Computers and other electronic
equipment will continue to operate without disruption because both the Filax and the
Phoenix Multi feature a very short switchover times (less than 20 milliseconds).
• Computer interface
All models rated at 1200 VA or more have a RS-485 computer interface. Together with the
VECon gure software, all parameters of the inverters can be customised. The inverters can
also be connected to VEnet, the new power control network of Victron Energy.
[ 12V: 180-5000 VA ]
[ 24V: 180-5000 VA ]
[ 48V: 180-5000 VA ]
BMV-600
Battery Monitor
Phoenix Inverter
Control (PIV)
Computer controlled
operation and
monitoring (Victron
Interface Mk2)
Battery Alarm An
excessively high
or low battery
voltage is indicated
by an audible and
visual alarm, and a
relay for remote
signailing.
1) Battery cables of 1.5 meter 2) Relay driver: open Collector 66V 3) Multipurpose relay which can be set for general alarm, DC undervoltage or
genset starts signal function 4) Suitable for parallel and 3-phase 5) Protection
a. Output short circuit b. Overload c. Battery voltage too high d. Battery voltage too low
e. Battery reverse polarity detection f. 230 V AC on inverter output g. Input voltage riplle too high h. Temperature too high
ACCESSORIES
Phoenix 12 Volt
inverter 14 Volt
48 Volt
12/180
24/180
48/180
12/350
24/350
48/350
12/750
24/750
48/750
C12/1200
C24/1200
C12/1600
C24/1600
C12/2000
C24/2000
12/3000
24/3000
48/3000
12/5000
24/5000
48/5000
Input voltage range (VCD) 10.5 - 15.5
21.0 - 31.0
42.0 - 62.0
10.5 - 15.5
21.0 - 31.0
42.0 - 62.0
10.5 - 15.5
21.0 - 31.0
42.0 - 62.0
9.5 - 16
19.5 - 32.2
9.5 - 16
19.5 - 33
9.5 - 16
19.5 - 33
9.5 - 16
19.5 - 33
38 - 66
9.5 - 16
19.5 - 33
38 - 66
Cont. output power at 25 ˚C (VA) 180 350 750 1200 1600 2000 3000 5000
Cont. power at 25 ˚C / 40 ˚C (W) 175 / 150 300 / 250 700 / 650 1000 / 900 (4) 1300 / 1200 (4) 1600 / 1450 (4) 2500 / 2000 (4) 4250 / 3350 (4)
Peak power (W)
(W)
200 500 1400 2200 2300
3000
4000 6000 7500
Max. E ciency 12/24/48 V (%) 91 / 92 / 92 90 / 91 / 92 91 / 93 / 94 93 / 94 93 / 94 93 / 94 93 / 94 / 95 92 / 94 / 95
Zero-load power 12/24/48V (w) 2.2 / 3.0 / 4.0 3.0 / 3.5 / 4.0 12 / 12 / 12 8 / 11 8 / 11 10 / 10 15 / 15 / 16 25 / 30 / 30
Zero-load power in AES mode n.a. n.a. 3/4/5 5/8 5/8 8/10 10/10/12 15/20/20
Muti purpose relay
driver or relay
relay driver (2) relay driver (2) relay driver (2) relay (3) relay (3)
Protection (5) a,b,d,h a,b,d,h a,b,d,h a,b,d,c,d,f,g,h a,b,d,c,d,f,g,h a,b,d,c,d,f,g,h a-h a-h
Common Characteristics Output: 230 V ± 2% /50/60 Hz ± 0,2% (switch selectable) Operating temperature range: -20 to +50˚C Humidity: max 95%
ENCLOSURE
Material & Colour Aluminium (blue RAL 5012)
Battery-connection 1) 1) Screw conn. 1) 1) M8 Studs M8 Studs 4 M8 bolts
230 V AC-connection IEC-320 (IEC-320 plug included) or Schuko G-ST18i G-ST18i Spring-clamp Screw-clamp
Protection category IP20 IP20 IP20 IP21 IP21 IP21 IP21 IP21
Weight (kg) 2.7 3.5 2.7 10 10 12 18 30
Dimensions (hxwxd in mm) 72x132x200 72x155x237 72x180x295 375x214x110 375x214x110 520x255x125 362x258x218 444x328x240
ACCESSORIES
Remote panel (RS485) √ (PIV) √ (PIV) √ (PIV) √ (PIV) √ (PIV)
Remote on-o switch√√√√
Automatic transfer switch FILAX FILAX FILAX Phoenix Multi Quattro
STANDARDS
Safety EN 60950 EN 60950 EN 60950 EN 60335-1 EN 60335-1 EN 60335-1 EN 60335-1 EN 60335-1
Emission / Imunnity EN 55014-1 / EN55014-2
Automotive Directive 95/54/EC and 2004/104/EC
Seitenansicht 2